ALP R-Anchor System
R-ANCHOR DIMENSIONS
Part # WD - Wire Diameter L - Length W - Width FW - Foot Width FD - Foot Diameter Weight (lbs) Anchor Ultimate Mechanical Load in Tension (lbs) LRA146G 1/4" 6" 2-11/16" 2-15/16" 1/2" 0.19 6,400 LRA516612G 5/16" 6-1/2" 2-5/8" 3" 3/4" 0.34 12,800 LRA387G 3/8" 7" 2-3/4" 3-7/16" 1" 0.55 18,760 LRA7169G 7/16" 9" 3-1/2" 3-7/8" 1" 1.08 30,000 LRA71611G 7/16" 11" 3-1/2" 3-7/8" 1" 1.28 30,000 Visit alpsupply.com for technical data sheets for the R-Anchor in ReCon, Redi-Rock , Verti-Block retaining wall systems.
R-ANCHOR LOAD CHART
30 30 Part # Description Installation Tension 4:1 SWL 60 Angle 4:1 SWL EH ED Min. Edge Distance 1,000 PSI (lbs) 1,500 PSI (lbs) 2,000 PSI (lbs) 2,500 PSI (lbs) 1,000 PSI (lbs) 1,500 PSI (lbs) 2,000 PSI (lbs) 2,500 PSI (lbs) LRA146G 1/4" x 6" 2-1/2" 3-1/2" 8" 1,525 1,600 LRA516612G 5/16" x 6-1/2" 0"* 7" 9" 3,200 2-1/2" 4" 9" 2,110 2,585 2,985 3,200 2,745 3,200 LRA387G 3/8" x 7" 0"* 7" 10" 4,690 2-1/2" 4-1/2" 10" 3,275 4,015 4,635 4,690 3,660 4,480 4,690 LRA7169G 7/16" x 9" 3" 6" 12" 5,475 6,700 7,500 6,555 7,500 LRA71611G 7/16" x 11" 3" 8" 12" 7,475 7,500 Indicates mechanical strength of anchor is achieved. *Recessed from concrete surface. For lifting and handling of thin slabs, design needs to ensure slab is properly reinforced to prevent flexural stresses from cracking slab. Above capacities are based upon mechanical testing and concrete testing.
Pulling sideways on one leg may reduce the capacity of the anchor. The ALP R-Anchor System is specially designed to be used in both recessed applications for retaining wall blocks and protruding from the concrete for small slabs. Standard finish is hot-dipped galvanized.
L FW W WD FD Anchor ID Lot # (> 3/8" anchors only) Min. Edge Distance EH - Exposed Height 90 ED - Embedment Depth 1/2" Min.
Wet set in concrete 02/2022 800.332.7090 sales@alpsupply.com alpsupply.com 80
R-ANCHORS AND LIFT LOOPS
Previous Page